Coherent’s 830 nm Wavelength Stabilized Laser is a high-power, multimode, single-axis collimated laser packaged in an ultra-compact, TO-can footprint. The narrowed linewidth, low power consumption, and broad temperature operating characteristics deliver affordable, portable instrument-quality performance for a broad range of instrumentation applications. All SureLock™ Series lasers are stabilized using the Coherent PowerLocker® Volume Holographic Grating, ensuring precise, ultra-stable center wavelengths, low temperature dependence, and consistent optical performance over the locked region.

830 nm Multimode, Collimated

TO-Can Laser for Instrumentation

Specification Summary

Parameter Symbol Min Typ Max Unit
Output Power Po 500 mW
Center Wavelength(vacuum) LP 829.5 830 830.5 nm
Linewidth Δλ 0.15 nm
Central Stabilized Temperature Tc 20 40 °C
Stabilized Temperature Range Tr 14 °C

SureLock™Specifications


Operating Specifications

Parameter Symbol Min Typ Max Unit
Threshold Current Ith 280 mA
Operating Current Iop 1000 900 mA
Operating Voltage Vop 1.9 2.2 V
Laser Reverse Voltage Vrl 2 V
Beam Size at Exit (FWHM) 1.0 x 0.5 mm
Emitter Size 1 x 100 µm
Beam Divergence Qv 0.25 x 3.5 Degrees
Differential Efficiency DE (dP/dI) 0.7 mW/mA
Operating Temperature1 Top 0 50 °C
Storage Temperature1 Ts -20 80 °C
Polarization 100:1
Polarization Orientation TE

SureLock™ Operating Specifications

1Non-Condensing

All specifications are at rated power with a case temperature of 25°C unless otherwise noted

Applications

Application

Raman Spectroscopy
Metrology
Bio-instrumentation
Sensing
Analytical Instrumentation

Features & Benefits


  • Collimated 9 mm TO-can package
  • Narrow spectral linewidth 0.15 nm
  • Wavelength stability 0.01 nm/°C
  • Fast axis collimated output beam
  • Narrow-band ASE filters available

Related Materials

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.